Merge "ARM: dts: msm: Add emergency mitigation for SDM845"
This commit is contained in:
commit
f7fa324be8
1 changed files with 176 additions and 0 deletions
|
|
@ -3503,6 +3503,182 @@
|
|||
};
|
||||
};
|
||||
|
||||
cpu0-silver-step {
|
||||
polling-delay-passive = <100>;
|
||||
polling-delay = <0>;
|
||||
thermal-sensors = <&tsens0 1>;
|
||||
thermal-governor = "step_wise";
|
||||
trips {
|
||||
emerg_config0: emerg-config0 {
|
||||
temperature = <110000>;
|
||||
hysteresis = <10000>;
|
||||
type = "passive";
|
||||
};
|
||||
};
|
||||
cooling-maps {
|
||||
emerg_cdev0 {
|
||||
trip = <&emerg_config0>;
|
||||
cooling-device =
|
||||
<&CPU0 THERMAL_MAX_LIMIT
|
||||
THERMAL_MAX_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
cpu1-silver-step {
|
||||
polling-delay-passive = <100>;
|
||||
polling-delay = <0>;
|
||||
thermal-sensors = <&tsens0 2>;
|
||||
thermal-governor = "step_wise";
|
||||
trips {
|
||||
emerg_config1: emerg-config1 {
|
||||
temperature = <110000>;
|
||||
hysteresis = <10000>;
|
||||
type = "passive";
|
||||
};
|
||||
};
|
||||
cooling-maps {
|
||||
emerg_cdev1 {
|
||||
trip = <&emerg_config1>;
|
||||
cooling-device =
|
||||
<&CPU1 THERMAL_MAX_LIMIT
|
||||
THERMAL_MAX_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
cpu2-silver-step {
|
||||
polling-delay-passive = <100>;
|
||||
polling-delay = <0>;
|
||||
thermal-sensors = <&tsens0 3>;
|
||||
thermal-governor = "step_wise";
|
||||
trips {
|
||||
emerg_config2: emerg-config2 {
|
||||
temperature = <110000>;
|
||||
hysteresis = <10000>;
|
||||
type = "passive";
|
||||
};
|
||||
};
|
||||
cooling-maps {
|
||||
emerg_cdev2 {
|
||||
trip = <&emerg_config2>;
|
||||
cooling-device =
|
||||
<&CPU2 THERMAL_MAX_LIMIT
|
||||
THERMAL_MAX_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
cpu3-silver-step {
|
||||
polling-delay-passive = <100>;
|
||||
polling-delay = <0>;
|
||||
thermal-sensors = <&tsens0 4>;
|
||||
thermal-governor = "step_wise";
|
||||
trips {
|
||||
emerg_config3: emerg-config3 {
|
||||
temperature = <110000>;
|
||||
hysteresis = <10000>;
|
||||
type = "passive";
|
||||
};
|
||||
};
|
||||
cooling-maps {
|
||||
emerg_cdev3 {
|
||||
trip = <&emerg_config3>;
|
||||
cooling-device =
|
||||
<&CPU3 THERMAL_MAX_LIMIT
|
||||
THERMAL_MAX_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
cpu0-gold-step {
|
||||
polling-delay-passive = <100>;
|
||||
polling-delay = <0>;
|
||||
thermal-sensors = <&tsens0 7>;
|
||||
thermal-governor = "step_wise";
|
||||
trips {
|
||||
emerg_config4: emerg-config4 {
|
||||
temperature = <110000>;
|
||||
hysteresis = <10000>;
|
||||
type = "passive";
|
||||
};
|
||||
};
|
||||
cooling-maps {
|
||||
emerg_cdev4 {
|
||||
trip = <&emerg_config4>;
|
||||
cooling-device =
|
||||
<&CPU4 THERMAL_MAX_LIMIT
|
||||
THERMAL_MAX_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
cpu1-gold-step {
|
||||
polling-delay-passive = <100>;
|
||||
polling-delay = <0>;
|
||||
thermal-sensors = <&tsens0 8>;
|
||||
thermal-governor = "step_wise";
|
||||
trips {
|
||||
emerg_config5: emerg-config5 {
|
||||
temperature = <110000>;
|
||||
hysteresis = <10000>;
|
||||
type = "passive";
|
||||
};
|
||||
};
|
||||
cooling-maps {
|
||||
emerg_cdev5 {
|
||||
trip = <&emerg_config5>;
|
||||
cooling-device =
|
||||
<&CPU5 THERMAL_MAX_LIMIT
|
||||
THERMAL_MAX_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
cpu2-gold-step {
|
||||
polling-delay-passive = <100>;
|
||||
polling-delay = <0>;
|
||||
thermal-sensors = <&tsens0 9>;
|
||||
thermal-governor = "step_wise";
|
||||
trips {
|
||||
emerg_config6: emerg-config6 {
|
||||
temperature = <110000>;
|
||||
hysteresis = <10000>;
|
||||
type = "passive";
|
||||
};
|
||||
};
|
||||
cooling-maps {
|
||||
emerg_cdev6 {
|
||||
trip = <&emerg_config6>;
|
||||
cooling-device =
|
||||
<&CPU6 THERMAL_MAX_LIMIT
|
||||
THERMAL_MAX_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
cpu3-gold-step {
|
||||
polling-delay-passive = <100>;
|
||||
polling-delay = <0>;
|
||||
thermal-sensors = <&tsens0 10>;
|
||||
thermal-governor = "step_wise";
|
||||
trips {
|
||||
emerg_config7: emerg-config7 {
|
||||
temperature = <110000>;
|
||||
hysteresis = <10000>;
|
||||
type = "passive";
|
||||
};
|
||||
};
|
||||
cooling-maps {
|
||||
emerg_cdev7 {
|
||||
trip = <&emerg_config7>;
|
||||
cooling-device =
|
||||
<&CPU7 THERMAL_MAX_LIMIT
|
||||
THERMAL_MAX_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
lmh-dcvs-01 {
|
||||
polling-delay-passive = <0>;
|
||||
polling-delay = <0>;
|
||||
|
|
|
|||
Loading…